Home » SNiPER Disinfectant Testing 1

SNiPER Disinfectant Testing 1

 

SNiPER DISINFECTANT TESTING

LA Testing Reference Number: 330600526

Hospital Disinfectant EPA Registration #71700-2-82482

CERTIFICATE OF ANALYSIS

Testing Protocol:

The AOAC Official method 961.02 Germicidal Spray Products as disinfectants was performed with Hospital Disinfectant #71700-2 on Leginella Pneumophila ATCC 33152 and Leuconostoc mesenteroides ATTCC 8293.

Bacterial test cultures of Leuconostoc mesenteroides were prepared using nutrient broth at 30 degrees C and Legionella pneumophila was prepared using Buffered charcoal Yeast extract agar, Mueller Hinton Broth with lysed horse blood and TAT broth at 37 degrees C.  The concentrations of the cultures was determined by standard plate count methods.

For each challenge organism, eleven sterile, glass slides were inoculated with 0.1 milliliter (ml) of inoculum broth each.  The slides were dried for 30 minutes at 37 degrees C.  One inoculated, untreated slide was used as a positive control and two uninoculated sterile slides were included as negative controls.  Product was sprayed onto 10 inoculated slides and one uninoculated slide for 10 seconds at a distance of one foot. After 10 minutes, the bacterial test and control slides were aseptically transferred to TAT broth and incubated for 48 hours at 30 degrees C.  A sterile blank tube was also included with each setup for media sterility verification.  After the defined incubation periods, the tubes were observed for growth.  Cloudiness in the broth indicates a positive sample.

Negative tubes were subcultured onto Trypicase Soy agar or Buffered Charcoal Yeast extract agar to verify the negative results.  They were also tested to rule out inhibitory effects as a cause for lack of growth.  This was done by adding 0.1 ml of the challenge organism to the negative tubes.  These were incubated for an additional 48 hours.  Growth of the challenge organism eliminates bateriostasis as a cause for negative results.

Killing of the test organism in 10 out of 10 trials is presumptive evidence of disinfecting action.  Viability (positive) controls should show growth and negative controls should have no growth.

Testing Results:

The results indicate that Broad Spectrum Disinfectant #717100-2 (SNiPER™) has a negative impact on both Leuconostoc mesenteroids and Legionella pneumophila.  After 10 minutes of exposure to the product, all challenge organisms were killed in 10 of 10 trials.  The positive controls exhibited growth while the negative controls all showed no growth.  After addition of each challenge organism to the negative tubes, growth occurred, ruling out stasis.

Challenge Organism Samples Negative Control  Positive Control
L. pneumophila  No Growth  Growth
L. mesenteroides    No Growth   Growth

LA Testing, Inc
Microbiology Division
10772 Noel Street
Los Alamitos, CA 90720

Analyst:  Regina Norman, Microbiology Laboratory Manager
Date:  January 31, 2006